TALOS C730
Automatic bollard for perimeter security
Automatic oil-hydraulic system, 230 Vac
Diameter | 275 |
Height | 1000 |
Thickness | 12 |
PERIMETER SECURITY
Intended for traffic control and protection of those sensitive areas (military stations, police headquarters, airports, etc.), where a high level of perimeter security is needed against terrorist attacks. Designed and tested to withstand, in a single bollard configuration, a vehicle of 7,5 t at a speed of 48 km/h.
OIL-HYDRAULIC
Hydraulic locking device in standing position (standard) and emergency manual lowering by a release spanner supplied with the equipment. Burglar-proof cover plate preventing the release system from being accessed and thus the bollard from being lowered.
STRONG
Scratch-proof cataphoresis treated and polyester powder coated steel rising cylinder. Available also with an AISI 304 stainless steel cover sleeve, thickness 12/10. Breakout resistance: 750.000 J.
Connector and junction box IP 66 for cabling. Hall effect limit switch sensors, cylinder head with rubber edge and incorporated LED lights.
VERSATILE
A vast range of command and safety accessories allow for reliable and precise control of the installations. Beeper to signal the movements. Heating device for installations in very low temperature conditions (-40 °C) where snow and ice are frequent. The electronic control unit can be set so that it can manage several bollards at a time.
CERTIFICATES
Classes of performance: K4 / M30 / C730
Certified: ASTM F2656-18A C730
PAS 68:2013 V/7500 (N3)/48
IWA 14-1:2013 V/7200 [N3C]/48
- Cylinder diameter (mm)275
- Cylinder thickness (mm)12
- Cylinder height from ground (mm)1.000
- Cylinder materialS355J2H steel
- Cylinder treatment and finishingcataphoresis and
polyester powder coating RAL 7016
AISI 304 brushed SS steel sleeve - Pithot dip galvanization
- Rising time (s) [cm/s]~5,00 [20]
- Lowering time (s) [cm/s]~4,20 [23]
- Working temperature (°C)-20 ÷ +80
(-40 with heater) - Oil type708L
- Power supply (Vac – Hz)230 - 50
- Absorbed power (W)1.850
- Absorbed current (A)5
- Grade of protection P / motor-pump67
- Frequency of use (cycles/day)heavy duty / 2.000
- Impact resistance (J)250.000
- Breakout resistance (J)750.000
- Maximum static load (kg)20.000